RES094Residential

Hybridization in parallel mode zone E1

Hybridization of a heating system in parallel mode (heat pump + boiler) for residential buildings in climatic zone E1.

Compliant with Orden TED/845/2023 · MITECO datasheet catalogue

Calculator RES094

Try the calculation without signing up. Results are not saved.

RES094Residential

Hybridization in parallel mode zone E1

Hybridization of a heating system in parallel mode (heat pump + boiler) for residential buildings in climatic zone E1.

Calculate automatically with intelligent technology

Upload the technical sheets, invoices or certificates of the equipment before and after the action. The parameters will be filled in automatically.

Limit: 0 / 10 documents (split between BEFORE and AFTER)

BEFORE the action

Existing equipment

Drag or click to upload

PDF, image, Word or Excel

AFTER the action

New equipment

Drag or click to upload

PDF, image, Word or Excel

Calculation parameters

Want to save this calculation and create a file? Create your free account

Calculation parameters

ParameterUnitDescription
Heating demandkWh/anoAnnual heating demand of the building (kWh/year).
Boiler efficiency%Seasonal efficiency of the existing boiler (%).
Heat pump SCOP-Seasonal coefficient of performance of the heat pump (SCOP).
Heat pump coverage%Percentage of demand covered by the heat pump (%).

Contexto de la hibridacion en modo paralelo en zona climatica E1

La zona climatica E1 es la mas fria de la clasificacion española, correspondiente a localidades de alta montana y meseta norte como Burgos capital, Molina de Aragon, Reinosa o Navacerrada. La ficha RES094 regula la emisión de CAE para sistemas hibridos en modo paralelo en estas condiciones extremas.

En zona E1, los inviernos son largos y rigurosos, con temperaturas que pueden descender de -15 grados centigrados. Esto plantea retos específicos para la bomba de calor, cuyo rendimiento desciende con la temperatura exterior. Sin embargo, la hibridacion sigue siendo beneficiosa porque durante gran parte de las horas de calefaccion las temperaturas se encuentran en un rango donde la bomba de calor supera claramente la eficiencia de la caldera.

Explicacion técnica del modo paralelo en zona E1

En la zona E1, el sistema hibrido en modo paralelo opera con una distribucion de carga distinta a la de zonas mas templadas. La caldera asume una fraccion mayor de la demanda, especialmente durante las noches invernales mas frias.

Caracteristicas de la zona E1

  • Grados-dia superiores a 2.500: puede superar los 3.000 K*dia/ano en las localidades mas frias
  • Temporada de calefaccion de 8-9 meses: solo julio y agosto quedan libres de necesidades de calor
  • Temperaturas de diseño extremas: hasta -15 grados centigrados
  • COP medio anual bajo: entre 2,2 y 2,8
  • Cobertura BC: entre el 50% y el 65% de la demanda anual

Ejemplo de calculo del ahorro y valoracion CAE

Hibridacion en modo paralelo en un edificio residencial en Burgos capital (zona E1).

Datos del ejemplo

  • Demanda calefaccion y ACS: 180.000 kWh/ano
  • Cobertura BC: 58%
  • COP medio anual: 2,50
  • Rendimiento caldera gasoleo: 88%

Calculo paso a paso

Demanda BC = 180.000 x 0,58 = 104.400 kWh/ano
Demanda caldera = 180.000 x 0,42 = 75.600 kWh/ano
Consumo EP hibrido = (104.400/2,50 x 1,954) + (75.600/0,88 x 1,190)
Consumo EP hibrido = 81.579 + 102.218 = 183.797 kWh/ano
Consumo EP solo caldera = 180.000/0,88 x 1,190 = 243.409 kWh/ano
Ahorro EP = 243.409 - 183.797 = 59.612 kWh/ano = 59,612 MWh/ano
CAE total = 59,612 MWh
Valoracion = 59,6 MWh x 100 EUR/MWh = 5.961 EUR

Errores comunes a evitar en la verificación ENAC

  • Bomba de calor no apta para baja temperatura: el equipo debe estar certificado para operar a -20 grados como mínimo
  • No instalar deposito de inercia: en zona E1, el deposito es esencial para evitar ciclos cortos de la bomba de calor
  • Cobertura BC optimista: la severa climatologia reduce la fraccion cubierta por la bomba de calor
  • No considerar el consumo de desescarche: los ciclos de desescarche frecuentes reducen el COP neto

Marco regulatorio aplicable

La ficha RES094 se ampara en la Orden TED/845/2023 y el Real Decreto 36/2023. La zona E1 presenta las condiciones climaticas mas extremas del CTE DB HE, con exigencias de aislamiento y rendimiento de instalaciones mas restrictivas. Las bombas de calor deben cumplir los requisitos de funcionamiento a baja temperatura del Reglamento (UE) 813/2013.

Required documents

  • D1Reference-situation documentation (existing equipment)
  • D2Technical documentation of the new equipment (datasheet, certificates)
  • D3Invoice or contract for the action
  • D4Before/after photographic report
  • D5Supporting savings calculation (generated automatically)

Related resources

Start now

Create a file with datasheet RES094

14 days free. No card. No commitment.

Start now